Groupe électrogène diesel industriel 60hz 220V 3 phases 880kw/1100kva CUMMINS avec prix de générateur compétitif
Informations de base
Modèle: OCL60-1100
Description du produit
2.60hz 220V triphasé
3.CUMMINS moteur KTA38-G2A
4.prix du générateur compétitif
5.longue durée de vie
60hz 220V triphasé 880kw/1100kva CUMMINS groupe électrogène diesel industriel avec compétitif prix du générateur Paramètre du générateur diesel industriel :
Main Technical data of generator set | ||||
Model | OCL60-1100 | |||
Prime Power | 800KW/1000kva | |||
Standby Power | 880KW/1100kva | |||
Rated Voltage | 110/220V | |||
Rated Current | 1500A | |||
Rated Frequency | 60HZ | |||
Rated Speed | 1800 rpm | |||
Overall Dimension | 4800*2060*2450mm | |||
Main Technical Data of Engine | ||||
Brand | CUMMINS | |||
Model | KTA38-G2A | |||
Prime Power, | 915KW | |||
standby power | 1007kw | |||
Governor Type | Electronic governor | |||
Cylinder Type | 12 cylinder in vee,direct injection | |||
Cooling Method | Water cooled | |||
Bore × Stroke | 140*152 mm | |||
Compression Ratio | 14.5:1 | |||
Displacement | 37.8L | |||
Starting Method | DC 24V electric start | |||
Fuel Consumption | ≤199g/kw.h | |||
coolant capacity | 325L | |||
fuel system | PT Fuel Injection Pump | |||
Main Technical Data of Alternator | ||||
Brand | Leadtech | |||
Model | LTG404E | |||
Prime Power | 850KW | |||
Excitation Mode | Brushless, self-exciting ,single bearing | |||
Prime Voltage | 110/220V | |||
Frequency | 60HZ | |||
Power Factor | 0.8(lagging) | |||
Phase/Wire | 3 phase 4 wires | |||
Insulation Grade | H | |||
Protection Class | IP22 | |||
Intelligent control system | ||||
Brand:Smartgen 6110/ Smartgen 6120with ATS( Automatic Transfer switches ) | ||||
Function:Over load protection; Generator over/under frequency protection:Generator over/under/unbalance voltage Protection Over load protection; Generator over/under frequency protection:Generator over/under/unbalance voltage Protection ,etc. | ||||
ATS(Automatic Transfer switches):optional | ||||
Function:Once the main power failure, the control panel will received the signal to start the genset within 5 seconds, ATS will switch to the load wires to connect genset power supply,and the whole process takes less than 15 seconds. After the main power recovered 30 seconds, ATS automatically switch the load wires to connect main power supply,the genset will stop after running 180 seconds. |